473,614 Members | 2,328 Online
Bytes | Software Development & Data Engineering Community
+ Post

Home Posts Topics Members FAQ

Rollforward after online backup

Ok W2K DB2 v8.1 fix pack 5.

On production I took a an online backup of production and copied it
over to my staging environment.
restored the production database on top of staging database redirect.
I copied over all the log files from production box to a temp
directory.

restore was complete with redirect and staging went into roll forward
pending.

RAN:
db2 rollforward db staging to end of logs com complete overflow log
path (d:\temp\logs)
got the following error
SQL1276N Database "WSWSTAGE" cannot be brought out of rollforward
pending
state until roll-forward has passed a point in time greater than or
equal to
"2004-09-30-14.58.53.000000 ", because node "0" contains information
later than
the specified time.
RAN:
db2 rollforward db staging query status

Rollforward Status

Input database alias = wswstage
Number of nodes have returned status = 1

Node number = 0
Rollforward status = DB working
Next log file to be read = S0103402.LOG
Log files processed = -
Last committed transaction = 2004-09-25-18.16.23.000000

can not rollforward complete and that log file is in the temp\logs
directory.

Any one have any idea why this would happen and what I could do to get
back my database.
Nov 12 '05 #1
1 9610
ra*******@yahoo .com (Steven) wrote in message news:<10******* *************** ****@posting.go ogle.com>...
Ok W2K DB2 v8.1 fix pack 5.

On production I took a an online backup of production and copied it
over to my staging environment.
restored the production database on top of staging database redirect.
I copied over all the log files from production box to a temp
directory.

restore was complete with redirect and staging went into roll forward
pending.

RAN:
db2 rollforward db staging to end of logs com complete overflow log
path (d:\temp\logs)
got the following error
SQL1276N Database "WSWSTAGE" cannot be brought out of rollforward
pending
state until roll-forward has passed a point in time greater than or
equal to
"2004-09-30-14.58.53.000000 ", because node "0" contains information
later than
the specified time.
RAN:
db2 rollforward db staging query status

Rollforward Status

Input database alias = wswstage
Number of nodes have returned status = 1

Node number = 0
Rollforward status = DB working
Next log file to be read = S0103402.LOG
Log files processed = -
Last committed transaction = 2004-09-25-18.16.23.000000

can not rollforward complete and that log file is in the temp\logs
directory.

Any one have any idea why this would happen and what I could do to get
back my database.


Y need to copy all the active log to your local directory also..
Nov 12 '05 #2

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

3
4375
by: Michelle | last post by:
Hi, I'm trying to rollforward my database to end of logs and complete, the first error message i get is - SQL6063N rollforward recovery on database X has stopped on node "0" due to change in log file size, when i re-issue the command I get the " unexpected system error occured" I also dropped the db and restored it again, but still getting the same errors.
1
2076
by: Juan Norton | last post by:
Got DB2 v8.2 WUE -Machine A runnig XP -Machine B " 2003 server I have the following error trying to do a hand rollforward on machice B: db2 => rollforward database BD to end of logs SQL1265N The archive log file "S0018161.LOG" is not as current log sequence for database "BD" on node "0".
3
3390
by: t2581 | last post by:
Hi , I run restore with rollforward In job in output, last commited transaction time less then backup image time Is it normal ? RESTORE DATABASE PRICE_V8 FROM "E:\BACKUP" TAKEN AT 20050610095841 TO "D:" INTO PR_READ NEWLOGPATH "D:\DB2_FILES\PR_READ\LOG" WITH 2 BUFFERS BUFFER 1024 REDIRECT PARALLELISM 1 WITHOUT PROMPTING .....
3
6230
by: dotyet | last post by:
Hi Everyone, I am in a very strange situation, and am looking for suggestions to tackle it. I have a 10 gig database on 64-bit windows 2003 running platform. The database has about 5 gigs of bufferpool. It's a DB2 UDB 8.2 FP9a database. I am trying to restore an online backup image of this database on a
18
5741
by: darnold | last post by:
I have restored a clients database using a redirected restore. However, it is in a roll forward pending state. When I try to to a roll forward to end of the logs, I get SQL1268N Roll-forward recovery stopped due to error "1" while retrieving log.... I have all of the logs, including the one mentioned in the SQL1268N message. And they are in the log directory I have tried changing userexit to no, and logretain to recovery.
3
2513
by: EC | last post by:
We have two DB2 servers are supposed to be a replicate of each other with a database of the same name. I want to do a 'db2 db backup online... include logs' on the first server, and do a 'db2 restore db to ... logtarget...' on the second server, and then rollforward ONLY those logs that were included in the backup image. Both databases may have the same DB id because of previous restores. However, the second server might have additional...
0
1372
by: smujifor | last post by:
Hello, I have a small confuction to rollforward logs after restore i found thru list history command like this Backup -1 Op Obj Timestamp+Sequence Type Dev Earliest Log Current Log Backup ID -- --- ------------------ ---- --- ------------ ------------ --------------
2
1795
by: satish mullapudi | last post by:
Hi, Am facing a tough situation & the scenario goes like this: I have scheduled online backup on a db. The online backup is scheduled to run daily at 12 in the night. Now am to restore the same db in another server . I have with me the backup image & 50 logs which I need to rollforward. When am trying to restore it is working fine & the db goes into ROLLFORWARD PENDING state as expected. When am trying to ROLLFORWARD the db, it is saying...
0
65303
by: shorti | last post by:
We are running DB2 UDB 8.1 fp 14 on AIX using archival logging and online backups. I was running some disaster tests and found my database restore was not restoring to the latest active log. Online backup include logs. For this test I created a disaster where we lost the database about 30 minutes after the last backup. Current archive and active logs were saved off and I ran a Restore of the latest backup and rollforward to the end of...
0
8640
Oralloy
by: Oralloy | last post by:
Hello folks, I am unable to find appropriate documentation on the type promotion of bit-fields when using the generalised comparison operator "<=>". The problem is that using the GNU compilers, it seems that the internal comparison operator "<=>" tries to promote arguments from unsigned to signed. This is as boiled down as I can make it. Here is my compilation command: g++-12 -std=c++20 -Wnarrowing bit_field.cpp Here is the code in...
0
8589
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven tapestry of website design and digital marketing. It's not merely about having a website; it's about crafting an immersive digital experience that captivates audiences and drives business growth. The Art of Business Website Design Your website is...
1
8287
by: Hystou | last post by:
Overview: Windows 11 and 10 have less user interface control over operating system update behaviour than previous versions of Windows. In Windows 11 and 10, there is no way to turn off the Windows Update option using the Control Panel or Settings app; it automatically checks for updates and installs any it finds, whether you like it or not. For most users, this new feature is actually very convenient. If you want to control the update process,...
0
7114
agi2029
by: agi2029 | last post by:
Let's talk about the concept of autonomous AI software engineers and no-code agents. These AIs are designed to manage the entire lifecycle of a software development project—planning, coding, testing, and deployment—without human intervention. Imagine an AI that can take a project description, break it down, write the code, debug it, and then launch it, all on its own.... Now, this would greatly impact the work of software developers. The idea...
1
6093
isladogs
by: isladogs | last post by:
The next Access Europe User Group meeting will be on Wednesday 1 May 2024 starting at 18:00 UK time (6PM UTC+1) and finishing by 19:30 (7.30PM). In this session, we are pleased to welcome a new presenter, Adolph Dupré who will be discussing some powerful techniques for using class modules. He will explain when you may want to use classes instead of User Defined Types (UDT). For example, to manage the data in unbound forms. Adolph will...
0
4058
by: TSSRALBI | last post by:
Hello I'm a network technician in training and I need your help. I am currently learning how to create and manage the different types of VPNs and I have a question about LAN-to-LAN VPNs. The last exercise I practiced was to create a LAN-to-LAN VPN between two Pfsense firewalls, by using IPSEC protocols. I succeeded, with both firewalls in the same network. But I'm wondering if it's possible to do the same thing, with 2 Pfsense firewalls...
0
4136
by: adsilva | last post by:
A Windows Forms form does not have the event Unload, like VB6. What one acts like?
1
1757
muto222
by: muto222 | last post by:
How can i add a mobile payment intergratation into php mysql website.
0
1438
bsmnconsultancy
by: bsmnconsultancy | last post by:
In today's digital era, a well-designed website is crucial for businesses looking to succeed. Whether you're a small business owner or a large corporation in Toronto, having a strong online presence can significantly impact your brand's success. BSMN Consultancy, a leader in Website Development in Toronto offers valuable insights into creating effective websites that not only look great but also perform exceptionally well. In this comprehensive...

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.