473,666 Members | 2,188 Online
Bytes | Software Development & Data Engineering Community
+ Post

Home Posts Topics Members FAQ

More messages in db2diag.log

When I run a backup script from the Task Center i get these messages:

2006-02-15-21.30.08.515000 +060 E21985H390 LEVEL: Error
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1418 APPID: *LOCAL.DB2.0602 15203021
FUNCTION: DB2 UDB, base sys utilities, sqleDatabaseQui esce, probe:1
MESSAGE : ADM7506W Database quiesce has been requested.

2006-02-15-21.30.08.515000 +060 E22377H406 LEVEL: Error
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1418 APPID: *LOCAL.DB2.0602 15203021
FUNCTION: DB2 UDB, base sys utilities, sqleDatabaseQui esce, probe:2
MESSAGE : ADM7507W Database quiesce request has completed successfully.

2006-02-15-21.30.09.265000 +060 I22785H391 LEVEL: Warning
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1071 APPID: *LOCAL.DB2.0602 15203022
FUNCTION: DB2 UDB, database utilities, sqlubSetupJobCo ntrol, probe:2028
MESSAGE : Starting an offline incremental db backup.

2006-02-15-21.30.36.437000 +060 I23178H353 LEVEL: Warning
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1071 APPID: *LOCAL.DB2.0602 15203022
FUNCTION: DB2 UDB, database utilities, sqlubcka, probe:130
MESSAGE : Backup Complete.

But I do not consider a database quiesce to be an error, nor a start and a
succesful completion of a database backup to deserve a warning. Can anyone
say anything about why db2 write these messages to the db2diag.log?

The diaglevel is set to 3.

Regards
Odd B Andersen
ErgoGroup, Oslo, Norway
Feb 16 '06 #1
2 2401
Odd Bjrn Andersen wrote:
When I run a backup script from the Task Center i get these messages:

2006-02-15-21.30.08.515000 +060 E21985H390 LEVEL: Error
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1418 APPID: *LOCAL.DB2.0602 15203021
FUNCTION: DB2 UDB, base sys utilities, sqleDatabaseQui esce, probe:1
MESSAGE : ADM7506W Database quiesce has been requested.

2006-02-15-21.30.08.515000 +060 E22377H406 LEVEL: Error
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1418 APPID: *LOCAL.DB2.0602 15203021
FUNCTION: DB2 UDB, base sys utilities, sqleDatabaseQui esce, probe:2
MESSAGE : ADM7507W Database quiesce request has completed successfully.

2006-02-15-21.30.09.265000 +060 I22785H391 LEVEL: Warning
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1071 APPID: *LOCAL.DB2.0602 15203022
FUNCTION: DB2 UDB, database utilities, sqlubSetupJobCo ntrol, probe:2028
MESSAGE : Starting an offline incremental db backup.

2006-02-15-21.30.36.437000 +060 I23178H353 LEVEL: Warning
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1071 APPID: *LOCAL.DB2.0602 15203022
FUNCTION: DB2 UDB, database utilities, sqlubcka, probe:130
MESSAGE : Backup Complete.

But I do not consider a database quiesce to be an error, nor a start and a
succesful completion of a database backup to deserve a warning. Can anyone
say anything about why db2 write these messages to the db2diag.log?

The diaglevel is set to 3.

Which fixpack level are you on?
When the db2diag.log was reorganized to classify the messages, it is
known that some classification were unfortunate.
The messages should be flaggs as "Warning" or "Info"

Cheers
Serge
--
Serge Rielau
DB2 Solutions Development
IBM Toronto Lab
Feb 16 '06 #2
Serge Rielau wrote:
Odd Bjrn Andersen wrote:
When I run a backup script from the Task Center i get these messages:

2006-02-15-21.30.08.515000 +060 E21985H390 LEVEL: Error
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1418 APPID: *LOCAL.DB2.0602 15203021
FUNCTION: DB2 UDB, base sys utilities, sqleDatabaseQui esce, probe:1
MESSAGE : ADM7506W Database quiesce has been requested.

2006-02-15-21.30.08.515000 +060 E22377H406 LEVEL: Error
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1418 APPID: *LOCAL.DB2.0602 15203021
FUNCTION: DB2 UDB, base sys utilities, sqleDatabaseQui esce, probe:2
MESSAGE : ADM7507W Database quiesce request has completed successfully.

2006-02-15-21.30.09.265000 +060 I22785H391 LEVEL: Warning
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1071 APPID: *LOCAL.DB2.0602 15203022
FUNCTION: DB2 UDB, database utilities, sqlubSetupJobCo ntrol, probe:2028
MESSAGE : Starting an offline incremental db backup.

2006-02-15-21.30.36.437000 +060 I23178H353 LEVEL: Warning
PID : 2408 TID : 3416 PROC : db2syscs.exe
INSTANCE: DB2 NODE : 000 DB : XDKE00
APPHDL : 0-1071 APPID: *LOCAL.DB2.0602 15203022
FUNCTION: DB2 UDB, database utilities, sqlubcka, probe:130
MESSAGE : Backup Complete.

But I do not consider a database quiesce to be an error, nor a start
and a succesful completion of a database backup to deserve a warning.
Can anyone say anything about why db2 write these messages to the
db2diag.log?

The diaglevel is set to 3.

Which fixpack level are you on?
When the db2diag.log was reorganized to classify the messages, it is
known that some classification were unfortunate.
The messages should be flaggs as "Warning" or "Info"

I passed it on to development to be fixed in Viper.

Cheers
Serge
--
Serge Rielau
DB2 Solutions Development
IBM Toronto Lab
Feb 16 '06 #3

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

3
5560
by: Odd Bjrn Andersen | last post by:
Every night at 21.30 we perform a full offline database backup. Just before the backup starts we do a db2stop/db2start. After the db2stop there is a message in the db2diag.log, and after the backup there is another message. And this happens every time. Here is an extract of the db2diag.log: 2004-03-01-21.30.38.812504 Instance:db2bpu1 Node:000 PID:25106(db2stop2) Appid:none base_sys_utilities stopdbm Probe:911 Database manager is...
3
1732
by: nycjay | last post by:
hello, i am just getting started as a dba. ny current task is to set up notification for health alerts. so, we have the health monitor running, and it is currently putting health alerts (space usage, runstat warnings, etc) into the normal db2diag logs. as i understand it, we can set up the admin server (das?) to send an email or page to a dba when one of these health alters is triggered. what we are trying to do is slightly different...
16
5477
by: Brian Tkatch | last post by:
I have a PROCEDURE that test other PROCEDUREs. Timings_Call ------------------ Id Group Name Text Timings_Log
38
3037
by: sopranos2 | last post by:
Dear IBM DB2 support, I wish CLP would have been more functional. Without living the command line I would like to get sql return code explanations, scalar function definitions etc.. Looking forward to see CLP enhancements in v8.3 -mike
14
3524
by: Gio Galma | last post by:
how I can invoke the db2diag utility in a Windows environment? in my D:\Program Files\IBM\SQLLIB\BIN directory I can see only db2diag.dll, and it seems there isn't the command line version; which is the DB2 tool that uses this dll, in order to analyze the db2diag.log? thank you in advance for help (and please, excuse my bad english) Jo --
5
3644
by: Gregor Kovač | last post by:
Hi! If I do IMPORT with ADMIN_CMD procedure and use MESSAGES ON SERVER option with IMPORT where are those messages stored? I know ADMIN_CMD returns a result set for IMPORT and an SQL I can get messages and remove them. Do I have to use the remove part to delete messages or not? I'm afraid that if I don't use the remove part something will get bigger and bigger and this will impact performance. Best regards,
1
5809
by: oddbande | last post by:
We have just upgraded a test enviroment to db2 9, and have set both the notifylevel and diaglevel to 3. But even so I get a lot of these messages in my db2diag.log: 2006-11-02-00.10.11.951000+060 I326548H465 LEVEL: Info PID : 3008 TID : 4072 PROC : db2dasstm.exe INSTANCE: DB2 NODE : 000 APPID : *LOCAL.DB2.061101231048 FUNCTION: DB2 UDB, DRDA Communication Manager, sqljcReceive,...
5
3218
by: Norm | last post by:
Does anyone have any suggestions for securing against this vulnerability: http://nvd.nist.gov/nvd.cfm?cvename=CVE-2007-1027 Fixes are not yet available from IBM. They will be in FP2 for V9 and FP15 for V8. Would changing the permissions on the db2dump directory so that only instance owner has access be enough?
0
3957
by: zhif | last post by:
I checked db2diag.log. There are the following two kinds of error messages (I) 2007-04-09-14.23.06.313673-240 I50090C517 LEVEL: Error PID : 54008 TID : 1 PROC : db2agentg (HAMDB2 ) 0 INSTANCE: db2inst1 NODE : 000 DB : CAT_DWGS APPHDL : 0-604 APPID: CF82B7D0.C6B9.070409152519 FUNCTION: DB2 UDB, DRDA Application...
0
8454
marktang
by: marktang | last post by:
ONU (Optical Network Unit) is one of the key components for providing high-speed Internet services. Its primary function is to act as an endpoint device located at the user's premises. However, people are often confused as to whether an ONU can Work As a Router. In this blog post, well explore What is ONU, What Is Router, ONU & Routers main usage, and What is the difference between ONU and Router. Lets take a closer look ! Part I. Meaning of...
0
8362
by: Hystou | last post by:
Most computers default to English, but sometimes we require a different language, especially when relocating. Forgot to request a specific language before your computer shipped? No problem! You can effortlessly switch the default language on Windows 10 without reinstalling. I'll walk you through it. First, let's disable language synchronization. With a Microsoft account, language settings sync across devices. To prevent any complications,...
0
8785
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven tapestry of website design and digital marketing. It's not merely about having a website; it's about crafting an immersive digital experience that captivates audiences and drives business growth. The Art of Business Website Design Your website is...
1
8560
by: Hystou | last post by:
Overview: Windows 11 and 10 have less user interface control over operating system update behaviour than previous versions of Windows. In Windows 11 and 10, there is no way to turn off the Windows Update option using the Control Panel or Settings app; it automatically checks for updates and installs any it finds, whether you like it or not. For most users, this new feature is actually very convenient. If you want to control the update process,...
0
8644
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each protocol has its own unique characteristics and advantages, but as a user who is planning to build a smart home system, I am a bit confused by the choice of these technologies. I'm particularly interested in Zigbee because I've heard it does some...
1
6200
isladogs
by: isladogs | last post by:
The next Access Europe User Group meeting will be on Wednesday 1 May 2024 starting at 18:00 UK time (6PM UTC+1) and finishing by 19:30 (7.30PM). In this session, we are pleased to welcome a new presenter, Adolph Dupr who will be discussing some powerful techniques for using class modules. He will explain when you may want to use classes instead of User Defined Types (UDT). For example, to manage the data in unbound forms. Adolph will...
0
5671
by: conductexam | last post by:
I have .net C# application in which I am extracting data from word file and save it in database particularly. To store word all data as it is I am converting the whole word file firstly in HTML and then checking html paragraph one by one. At the time of converting from word file to html my equations which are in the word document file was convert into image. Globals.ThisAddIn.Application.ActiveDocument.Select();...
0
4200
by: TSSRALBI | last post by:
Hello I'm a network technician in training and I need your help. I am currently learning how to create and manage the different types of VPNs and I have a question about LAN-to-LAN VPNs. The last exercise I practiced was to create a LAN-to-LAN VPN between two Pfsense firewalls, by using IPSEC protocols. I succeeded, with both firewalls in the same network. But I'm wondering if it's possible to do the same thing, with 2 Pfsense firewalls...
2
2012
muto222
by: muto222 | last post by:
How can i add a mobile payment intergratation into php mysql website.

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.