We are running DB2 V8 on Solaris 9. Last week we upgraded from FP7 to
FP13. Everything seemed to be fine, but yesterday we were confronted
with a strange behavior of the DB2 governor.

An application server process was forced by the governor with this log
message:

2006-10-23-12.51.43 0 FORCE applname `panh030` authid `ARNRUN`
applid C0A80401.O256.0 3A012212902` coord 0 (line 56) ET 4294967295

The rule on line 56 is a general rule to force processes with 10 hours
of idletime or uowtime. Both didn't apply to the process in question.

But the interesting fact is the "ET 4294967295" entry. In hex this is
0xffffffff equaling -1. That looks very much like an signed-unsigned
issue. I also found a closed APAR about a similar problem (IY73972,
http://www-1.ibm.com/support/docview...d=swg1IY73972). The problem
was fixed in FP11, but it seems there is another problem.

Has anyone seen this before?

Paul Herger

Oct 24 '06 #1
0 1347

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

2
5886
by: Garry Clarke | last post by:
I have enabled the query governor on our SQL2000 SP2 server with a threshold of 3600. Now, some of the maintenance jobs fail due to the limit being to low (e.g. one of the user databases integrity check fails nightly). I have tried to put the command 'SET QUERY_GOVERNOR_COST_LIMIT 0' just before the line in the step which reads 'EXECUTE master.dbo.xp_sqlmaint N'-Plan etc' but it has no effect.
0
268
by: Olli Krollmann | last post by:
hello folks, we have been developing several .NET-based windows forms applications during the last two years. there are two mysterious display problems that we have encountered so far but have been unable to find any information about: 1. distorted fonts. when placing label controls on forms or setting form or grid captions we often notice that the label or title text is stretched out in the left part, displays correctly in the middle...
2
1281
by: Brian Cryer | last post by:
I'm working on a VB.NET project where we are intending to use MSDE as our back-end database. The actual number of users is expected to be low and I don't have any concerns as to whether MSDE will be up to the job (most of the time). I'm aware that if we end up with lots of users connecting to our site at once (which may happen as certain times in the year when people need information for deadlines) then the performance governor in MSDE will...
4
2858
by: Thiru | last post by:
Hi, Greetings to All. I have encountered a problem while working on DB2 Governer. I build my configuration file as below.(Just for practise) desc "Restrict the Unit of Work to be less then 1 minutes" setlimit uowtime 60 action force; I have started my db2 governer service and issued the following command
9
23088
by: Abhishek Srivastava | last post by:
Hello All, In IIS 6.0 We have a concept of worker processes and application pools. As I understand it, we can have multiple worker process per appliction pool. Each worker process is dedicated to a pool. If I assign only one application to a applicaton pool and have multiple worker processes assigned to that pool. Will my application be processed by many worker processes?
35
4050
by: Carl J. Van Arsdall | last post by:
Alright, based a on discussion on this mailing list, I've started to wonder, why use threads vs processes. So, If I have a system that has a large area of shared memory, which would be better? I've been leaning towards threads, I'm going to say why. Processes seem fairly expensive from my research so far. Each fork copies the entire contents of memory into the new process. There's also a more expensive context switch between...
2
3339
by: P. Adhia | last post by:
Hi, setlimit configuration file clause, applies to each SQL, UOW or connection. Only setlimit uowtime is specifically mentioned as elapsed time since the start of UOW. For example if I have, setlimit cpu 60; action force;
2
1652
by: matias.cornejo | last post by:
I have some users that have 5 or 6 connections with the same login at the same time. I want to limit that each user can have less than 3 connectios per login. How can I do that?? Thanks in advance
0
1736
by: lesmith | last post by:
db2 governor failing with connection refused -------------------------------------------------------------------------------- We are trying to test using the db2 governor (udb v8) and get a message "connection refused" following the db2 start gov command. Has anyone seen this ...or any ideas on what to check? details Trying ::ffff:159.202.148.9... connect to address ::ffff:159.202.148.9: Connection refused Trying...
0
9718
marktang
by: marktang | last post by:
ONU (Optical Network Unit) is one of the key components for providing high-speed Internet services. Its primary function is to act as an endpoint device located at the user's premises. However, people are often confused as to whether an ONU can Work As a Router. In this blog post, we’ll explore What is ONU, What Is Router, ONU & Router’s main usage, and What is the difference between ONU and Router. Let’s take a closer look ! Part I. Meaning of...
0
9596
by: Hystou | last post by:
Most computers default to English, but sometimes we require a different language, especially when relocating. Forgot to request a specific language before your computer shipped? No problem! You can effortlessly switch the default language on Windows 10 without reinstalling. I'll walk you through it. First, let's disable language synchronization. With a Microsoft account, language settings sync across devices. To prevent any complications,...
0
10363
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven tapestry of website design and digital marketing. It's not merely about having a website; it's about crafting an immersive digital experience that captivates audiences and drives business growth. The Art of Business Website Design Your website is...
1
10368
by: Hystou | last post by:
Overview: Windows 11 and 10 have less user interface control over operating system update behaviour than previous versions of Windows. In Windows 11 and 10, there is no way to turn off the Windows Update option using the Control Panel or Settings app; it automatically checks for updates and installs any it finds, whether you like it or not. For most users, this new feature is actually very convenient. If you want to control the update process,...
0
10107
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each protocol has its own unique characteristics and advantages, but as a user who is planning to build a smart home system, I am a bit confused by the choice of these technologies. I'm particularly interested in Zigbee because I've heard it does some...
0
9186
agi2029
by: agi2029 | last post by:
Let's talk about the concept of autonomous AI software engineers and no-code agents. These AIs are designed to manage the entire lifecycle of a software development project—planning, coding, testing, and deployment—without human intervention. Imagine an AI that can take a project description, break it down, write the code, debug it, and then launch it, all on its own.... Now, this would greatly impact the work of software developers. The idea...
0
6876
by: conductexam | last post by:
I have .net C# application in which I am extracting data from word file and save it in database particularly. To store word all data as it is I am converting the whole word file firstly in HTML and then checking html paragraph one by one. At the time of converting from word file to html my equations which are in the word document file was convert into image. Globals.ThisAddIn.Application.ActiveDocument.Select();...
0
5544
by: TSSRALBI | last post by:
Hello I'm a network technician in training and I need your help. I am currently learning how to create and manage the different types of VPNs and I have a question about LAN-to-LAN VPNs. The last exercise I practiced was to create a LAN-to-LAN VPN between two Pfsense firewalls, by using IPSEC protocols. I succeeded, with both firewalls in the same network. But I'm wondering if it's possible to do the same thing, with 2 Pfsense firewalls...
3
3008
bsmnconsultancy
by: bsmnconsultancy | last post by:
In today's digital era, a well-designed website is crucial for businesses looking to succeed. Whether you're a small business owner or a large corporation in Toronto, having a strong online presence can significantly impact your brand's success. BSMN Consultancy, a leader in Website Development in Toronto offers valuable insights into creating effective websites that not only look great but also perform exceptionally well. In this comprehensive...

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.