Query to linked server:Oracle; problems with ANSI_NULLS;ANSI _WARNINGS

When I perform a query on a linked Oracle server in the Query analyser I
have no
prboblem' to perform this query.
However, when I create this query in a stored procedure I get a compilation
error
when saving this procedure. (Not when compiling; it has no errors)

Server: Msg 7405, Level 16, State 1, Line 1
Heterogeneous queries require the ANSI_NULLS and ANSI_WARNINGS options
to be set for the connection. This ensures consistent query semantics.
Enable these options and then reissue your query.

When I create a dynamic SQL statement then I can save this stored procedure
when I run the stored procedure this same error happens.

What do I have to do.

Arno de Jong, The Netherlands
Jul 20 '05 #1
1 8557

"A.M. de Jong" <ar****@wxs.n l> wrote in message
news:bq******** **@reader11.wxs .nl...
When I perform a query on a linked Oracle server in the Query analyser I
have no
prboblem' to perform this query.
However, when I create this query in a stored procedure I get a compilation error
when saving this procedure. (Not when compiling; it has no errors)

Server: Msg 7405, Level 16, State 1, Line 1
Heterogeneous queries require the ANSI_NULLS and ANSI_WARNINGS options
to be set for the connection. This ensures consistent query semantics.
Enable these options and then reissue your query.

When I create a dynamic SQL statement then I can save this stored procedure when I run the stored procedure this same error happens.

What do I have to do.

Arno de Jong, The Netherlands


Have you tried putting SET ANSI_NULLS ON and SET ANSI_WARNINGS ON at the
start of your stored procedure, ie. in the procedure code itself? QA sets
these on automatically, but other connections may not.

Simon
Jul 20 '05 #2

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

0
5358
by: Jef S | last post by:
------=_NextPart_000_002B_01C34718.7E9AFEA0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit Greetings to all, Using a SELECT Statement, I am trying to pull information from two separate databases. The query is being run from the database entitled NETWORK and the other database is called DB1. The result set will be
5
7282
by: Warren Wright | last post by:
Hi group, I have a select statement that if run against a 1 million record database directly in query analyzer takes less than 1 second. However, if I execute the select statement in a stored procedure instead, calling the stored proc from query analyzer, then it takes 12-17 seconds. Here is what I execute in Query Analyzer when bypassing the stored procedure:
3
10749
by: Matt Rink | last post by:
Getting an "incorrect settings: 'ANSI_NULLS., QUOTED_IDENTIFIER'." error after creating a view. We wanted a composite unique constraint that ignored nulls, so we set up a view using the following script: /* --- start --- */ BEGIN TRANSACTION SET QUOTED_IDENTIFIER ON SET ARITHABORT ON
22
3045
by: Robert Brown | last post by:
suppose I have the following table: CREATE TABLE (int level, color varchar, length int, width int, height int) It has the following rows 1, "RED", 8, 10, 12 2, NULL, NULL, NULL, 20 3, NULL, 9, 82, 25
3
1750
by: Tracey | last post by:
I am having a problem with a procedure. I can run it from QA and it takes 50 minutes. When I have it in a scheduled job, it takes 3 hours!! What could be the cause of this? Why the big time difference? Thanks
3
23495
by: Iqbal | last post by:
Hi, I am getting the following error when I run a stored procedure in which I am inserting/deleting data from a view that selects from a remote table. INSERT failed because the following SET options have incorrect settings: 'ARITHABORT' The first statement in the stored procedure is 'set arithabort on'. I
2
8066
by: Adnan | last post by:
Hi Guys, I have one stored procedure on SQL 6.5 and retrieving data from SQL 2000. I have defined a linked server on SQL 6.5. But I am getting following error:- "Heterogeneous queries require the ANSI_NULLS and ANSI_WARNINGS options to be set for the connection. This ensures consistent query semantics. Enable these options and then reissue your query."
1
1429
by: Calvin Slater | last post by:
It is recommended that the following settings be set for all connections so that the optimizer will perform well on indexed views and stuff. SET QUOTED_IDENTIFIER ON SET ARITHABORT ON SET CONCAT_NULL_YIELDS_NULL ON SET ANSI_NULLS ON SET ANSI_PADDING ON SET ANSI_WARNINGS ON
0
1772
by: Gosth in the shell | last post by:
Hi there, i need some help I got a software to backend is MSSQL 2005, but a provider software requires an UPDATE on his table with MySQL 5.0.56a backend, so i made the next: download and install ODBC MySQL 3.51 configuring system DSN add a linked server on MSSQL 2005
0
8562
by: Hystou | last post by:
Most computers default to English, but sometimes we require a different language, especially when relocating. Forgot to request a specific language before your computer shipped? No problem! You can effortlessly switch the default language on Windows 10 without reinstalling. I'll walk you through it. First, let's disable language synchronization. With a Microsoft account, language settings sync across devices. To prevent any complications,...
1
8830
by: Hystou | last post by:
Overview: Windows 11 and 10 have less user interface control over operating system update behaviour than previous versions of Windows. In Windows 11 and 10, there is no way to turn off the Windows Update option using the Control Panel or Settings app; it automatically checks for updates and installs any it finds, whether you like it or not. For most users, this new feature is actually very convenient. If you want to control the update process,...
0
8820
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each protocol has its own unique characteristics and advantages, but as a user who is planning to build a smart home system, I am a bit confused by the choice of these technologies. I'm particularly interested in Zigbee because I've heard it does some...
0
7655
agi2029
by: agi2029 | last post by:
Let's talk about the concept of autonomous AI software engineers and no-code agents. These AIs are designed to manage the entire lifecycle of a software development project—planning, coding, testing, and deployment—without human intervention. Imagine an AI that can take a project description, break it down, write the code, debug it, and then launch it, all on its own.... Now, this would greatly impact the work of software developers. The idea...
1
6488
isladogs
by: isladogs | last post by:
The next Access Europe User Group meeting will be on Wednesday 1 May 2024 starting at 18:00 UK time (6PM UTC+1) and finishing by 19:30 (7.30PM). In this session, we are pleased to welcome a new presenter, Adolph Dupré who will be discussing some powerful techniques for using class modules. He will explain when you may want to use classes instead of User Defined Types (UDT). For example, to manage the data in unbound forms. Adolph will...
0
4339
by: TSSRALBI | last post by:
Hello I'm a network technician in training and I need your help. I am currently learning how to create and manage the different types of VPNs and I have a question about LAN-to-LAN VPNs. The last exercise I practiced was to create a LAN-to-LAN VPN between two Pfsense firewalls, by using IPSEC protocols. I succeeded, with both firewalls in the same network. But I'm wondering if it's possible to do the same thing, with 2 Pfsense firewalls...
0
4575
by: adsilva | last post by:
A Windows Forms form does not have the event Unload, like VB6. What one acts like?
1
2997
by: 6302768590 | last post by:
Hai team i want code for transfer the data from one system to another through IP address by using C# our system has to for every 5mins then we have to update the data what the data is updated we have to send another system
3
1971
bsmnconsultancy
by: bsmnconsultancy | last post by:
In today's digital era, a well-designed website is crucial for businesses looking to succeed. Whether you're a small business owner or a large corporation in Toronto, having a strong online presence can significantly impact your brand's success. BSMN Consultancy, a leader in Website Development in Toronto offers valuable insights into creating effective websites that not only look great but also perform exceptionally well. In this comprehensive...