Hi,

I've got this dts package in sql server 2000 sp4 that has several
transformation tasks with an oracle database (10g) as the destination.
The package executes successfully when run through the dts designer but
when run using dtsrun, I get the following error at the completion of
all tasks in the dts package. The data inserts into the oracle database
but i always get this Application error

The Instruction at "0x7c8327f9 " referenced memory at "Oxffffffff ". The
memory could not be "read"

Does anyone know how I can fix this?

Thanks
Lyn

Oct 26 '05 #1
2 3208
Hi

I am not sure why this should happen but you may want to check that your
arguements are correct http://support.microsoft.com/?kbid=308801 and that
you can the same versions of MDAC on the machine it is running on and that
it is consistent (see MDAC component checker http://tinyurl.com/6gsv )
http://support.microsoft.com/?kbid=255900

John
<ly*******@gmai l.com> wrote in message
news:11******** *************@g 43g2000cwa.goog legroups.com...
Hi,

I've got this dts package in sql server 2000 sp4 that has several
transformation tasks with an oracle database (10g) as the destination.
The package executes successfully when run through the dts designer but
when run using dtsrun, I get the following error at the completion of
all tasks in the dts package. The data inserts into the oracle database
but i always get this Application error

The Instruction at "0x7c8327f9 " referenced memory at "Oxffffffff ". The
memory could not be "read"

Does anyone know how I can fix this?

Thanks
Lyn

Oct 29 '05 #2
Hi John,

The mdac problem is relevant to sql server 7.0 and I've checked the
other kb. I don't pass any arguments. I have already got the latest
service pack installed for sql server 2000.

Lyn

John Bell wrote:
Hi

I am not sure why this should happen but you may want to check that your
arguements are correct http://support.microsoft.com/?kbid=308801 and that
you can the same versions of MDAC on the machine it is running on and that
it is consistent (see MDAC component checker http://tinyurl.com/6gsv )
http://support.microsoft.com/?kbid=255900

John
<ly*******@gmai l.com> wrote in message
news:11******** *************@g 43g2000cwa.goog legroups.com...
Hi,

I've got this dts package in sql server 2000 sp4 that has several
transformation tasks with an oracle database (10g) as the destination.
The package executes successfully when run through the dts designer but
when run using dtsrun, I get the following error at the completion of
all tasks in the dts package. The data inserts into the oracle database
but i always get this Application error

The Instruction at "0x7c8327f9 " referenced memory at "Oxffffffff ". The
memory could not be "read"

Does anyone know how I can fix this?

Thanks
Lyn


Oct 31 '05 #3

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

4
3440
by: Askari | last post by:
Yesterday, ALL code in python work and nothing when I close(finish) a code. Today, when I close, some raise this windows error : Instruction at "0x00FC3D70" use memory address "0x00000000". Can't be "read". Click on "OK" to exit program. Why this error, today and not before today?
3
9603
by: Justin To via AccessMonster.com | last post by:
I just distributed a FE mde file throught my department, and while stress testing on the performance of the new release, 3 users got the following error: The instruction at ... referenced memory at ... The memory cannot be "read". this seems like a computer-local problem as I cannot reproduce the same error on any other computers I tried running Dr. Watson (win2k) and it says "Exception number: c0000005
0
2145
by: antsays | last post by:
I am trying to serialize a collection to disk using the code provided. This works just fine but when I try do copy and past the xml file to another location or sometimes even just click on the file it gives me the error: The instruction at "0x635e0719" referenced memory at "0x00000000". The momory could not be "read. Could anyone please help out with this
4
16641
by: GVK | last post by:
Hi, I'm facing another problem with my network program. I'm writing a basic server that handles multiple clients. Whenever a client is connected, a new thread is created to handle it. The socket descriptor of the client and it's sockaddr_in structure are passed as arguments to the function that handles the client. Now, the following code is giving me an error. It's the function that handles the client:...
1
2040
by: Jim Tarrant | last post by:
Hi, When I run our application under PurifyPlus, I get lots of "UMR: Uninitialized memory read" warnings, e.g. UMR: Uninitialized memory read in std::_Tree_nod<class std::_Tmap_traits<class std::basic_string<char,struct std::char_traits<char>,class std::allocator<char> >,class CTCSystem *,struct std::less<class std::basic_string<char,struct std::char_traits<char>,class std::allocator<char> > >,class std::allocator<struct...
2
5197
by: Ryan Linneman via .NET 247 | last post by:
Any help appreciated... I am using a third party DLL file to access an HMI using ethernet. The function is declared in a VB module as: 'Read internal word address Public Declare Function HKEtn_ReadInternalMemory Lib "HKEserv.dll" _ (ByRef dp As Int16, _ ByVal Wordcnt As Int16, _ ByVal DeviceType As Int32, _ ByVal addr As Int32, _
1
2900
by: Curten | last post by:
Hi, When I run a program I have made, i get this error message sometimes: "Application error:The instruction at '...' referenced memory at '...'. Memory could not be "read"..." Are there any common mistakes that cause this problem? Before i get the message above i get this in the command window: "pow: OVERFLOW error". I suppose these error messages are connected, but how? What causes pow: OVERFLOW error?
1
4000
by: suresh810in | last post by:
hi, I got thsi error --------------------------- VB6.EXE - Application Error --------------------------- The instruction at "0x0055a8ea" referenced memory at "0x608af85c". The memory could not be "read". Click on OK to terminate the program Click on CANCEL to debug the program ---------------------------
1
3763
by: kamcap | last post by:
I have referenced a COM dll (unmanagged code) in a C# console application and this DLL is referenced in C# program using Interop facility in .NET. This dll actually a dataset/table which is written in Borland Delphi. static int Main(string args) { ClientVarDataSet vds = new ClientVarDataSet(); vds.XML = ""; vds.AddField("x", 3); //"x" field name and 3 field type
0
9923
marktang
by: marktang | last post by:
ONU (Optical Network Unit) is one of the key components for providing high-speed Internet services. Its primary function is to act as an endpoint device located at the user's premises. However, people are often confused as to whether an ONU can Work As a Router. In this blog post, we’ll explore What is ONU, What Is Router, ONU & Router’s main usage, and What is the difference between ONU and Router. Let’s take a closer look ! Part I. Meaning of...
0
11083
Oralloy
by: Oralloy | last post by:
Hello folks, I am unable to find appropriate documentation on the type promotion of bit-fields when using the generalised comparison operator "<=>". The problem is that using the GNU compilers, it seems that the internal comparison operator "<=>" tries to promote arguments from unsigned to signed. This is as boiled down as I can make it. Here is my compilation command: g++-12 -std=c++20 -Wnarrowing bit_field.cpp Here is the code in...
1
10808
by: Hystou | last post by:
Overview: Windows 11 and 10 have less user interface control over operating system update behaviour than previous versions of Windows. In Windows 11 and 10, there is no way to turn off the Windows Update option using the Control Panel or Settings app; it automatically checks for updates and installs any it finds, whether you like it or not. For most users, this new feature is actually very convenient. If you want to control the update process,...
0
10394
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each protocol has its own unique characteristics and advantages, but as a user who is planning to build a smart home system, I am a bit confused by the choice of these technologies. I'm particularly interested in Zigbee because I've heard it does some...
0
9549
agi2029
by: agi2029 | last post by:
Let's talk about the concept of autonomous AI software engineers and no-code agents. These AIs are designed to manage the entire lifecycle of a software development project—planning, coding, testing, and deployment—without human intervention. Imagine an AI that can take a project description, break it down, write the code, debug it, and then launch it, all on its own.... Now, this would greatly impact the work of software developers. The idea...
1
7940
isladogs
by: isladogs | last post by:
The next Access Europe User Group meeting will be on Wednesday 1 May 2024 starting at 18:00 UK time (6PM UTC+1) and finishing by 19:30 (7.30PM). In this session, we are pleased to welcome a new presenter, Adolph Dupré who will be discussing some powerful techniques for using class modules. He will explain when you may want to use classes instead of User Defined Types (UDT). For example, to manage the data in unbound forms. Adolph will...
0
5774
by: TSSRALBI | last post by:
Hello I'm a network technician in training and I need your help. I am currently learning how to create and manage the different types of VPNs and I have a question about LAN-to-LAN VPNs. The last exercise I practiced was to create a LAN-to-LAN VPN between two Pfsense firewalls, by using IPSEC protocols. I succeeded, with both firewalls in the same network. But I'm wondering if it's possible to do the same thing, with 2 Pfsense firewalls...
0
5971
by: adsilva | last post by:
A Windows Forms form does not have the event Unload, like VB6. What one acts like?
1
4592
by: 6302768590 | last post by:
Hai team i want code for transfer the data from one system to another through IP address by using C# our system has to for every 5mins then we have to update the data what the data is updated we have to send another system

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.