Convert native byte array (pointer) to managed byte[]

We are writing some code to interface to a DLL. The DLL
has a callback method that returns the address of a byte
buffer and the buffer length. I have defined the byte
pointer as an IntPtr.

How do I convert between the IntPtr and my managed byte[]
that I want to copy the data into???

-dave
Jul 19 '05 #1
1 11348
System.Runtime.InteropServices.Marshal.Copy(IntPtr source, byte[]
destination, int start, int length)

"Dave" <dh*****@xrite.remove.com> wrote in message
news:10****************************@phx.gbl...
We are writing some code to interface to a DLL. The DLL
has a callback method that returns the address of a byte
buffer and the buffer length. I have defined the byte
pointer as an IntPtr.

How do I convert between the IntPtr and my managed byte[]
that I want to copy the data into???

-dave

Jul 19 '05 #2