473,396 Members | 1,827 Online
Bytes | Software Development & Data Engineering Community
Post Job

Home Posts Topics Members FAQ

Join Bytes to post your question to a community of 473,396 software developers and data experts.

DB2 error in DB2 control center

5
Hello,
I have been trying to enter SQL statmenbts to DB2 control center command line.
I saw that user "Thames" wrote to you:
> I have to repost my question for help.
>
> Yesterday I set up two DB UDB ESE V8.2 server on linux and windows
> platform, respectively. Both servers have been connected without any
> problems
> However, It gave me such error when I tried to make db connection via
> command prompt(windows)
>
> db2 connect to sample
>
> --------------
> SQL0332N there is no available conversion for the source code page
> "1252" to the target code page "1386". reason Code "1" SQLSTATE=57017
> --------------
>
> The strange thing is I can still see sample database connected from
> control center and also there is no problem with db object access in
> control center
>
> Also I can connect this sample db (in windows) from remote linux server
> I really do not know why I cannot connect to db sample locally using
> windows command prompt
>
> thanks
you wrote to him about the reasons:
>Explanation:

>No conversion of data is supported from the source code page to
>the target code page. This error can occur under the following
>conditions:
>
>o An error has occurred executing an SQL statement. The data
>cannot be processed by the database manager.
>
>o An error has occurred when trying to import or export a WSF
>or an IXF file. The import or export will fail.
>
>o Federated system users: the data source does not support the
>specified code page conversion.
>
>o DB2 Connect users: both "source code page" and "target code
>page" may refer to a CCSID on the host or AS/400 system.
>
>o An error has occurred during conversion from the code page
>stored with the encrypted data to the target code page.
>
>
>
>The reason codes are as follows:
>
>
>1 source and target code page combination is not supported by
>the database manager.
>
>2 source and target code page combination is either not
>supported by the database manager or by the operating system
>character conversion utility on the client node.
>
>3 source and target code page combination is either not
>supported by the database manager or by the operating system
>character conversion utility on the server node.
and you wrote about the solutions:
>o Verify that data conversion between the source and target
>code page is supported by the database manager. For
>database manager code page support, check the Quick
>Beginnings . If DB2 Connect is being used, check the DB2
>Connect Quick Beginnings .
What is data base code support?How do I get to it?
>o Change the unsupported code page(s) to one of the documented
>pairs.
How do I get to the unsupported code page(s) to change them?
You also wrote:
>You should verify what kind of code page setting you use in the DB2 command
>window and which code page is set for the database.
How do I verify this kind of information?
Thanks,
Yoav
Sep 25 '08 #1
0 3092

Sign in to post your reply or Sign up for a free account.

Similar topics

2
by: Jack | last post by:
The following is the error: Error Type: Microsoft JET Database Engine (0x80040E14) Syntax error (missing operator) in query expression 'ApplicantIntID ='. /subgrantapptest/ListSaved.asp, line...
1
by: Sean C. | last post by:
Helpful folks, I have recently migrated our test server, which runs Win NT 4, from V7.2 FP11 to V8.1.3. Just about everything works wondefully, except I am having major problems getting the...
12
by: Raed Sawalha | last post by:
I have the following table which i can not switcha to design view error message said Could not open in Design view. Quote values differently inside a '<% ...."value"... %>' block. and the...
3
by: tjonsek | last post by:
am working on code that will allow users to update data within the datagrid. I have come across a few problems, some of them I have been able to work out, but this last one is giving me trouble. ...
3
by: scoffer | last post by:
Hi all, I have a problem when I try to open the tables list on a database. I work with 8.2.0 Enterprise Edition. The control center return this error: SQL0104N E' stato trovato un token...
0
by: DC | last post by:
The problem I'm using the .NET GridView and FormView objects for the first time and im getting the error "An OleDbParameter with ParameterName '@ID' is not contained by this...
2
by: =?Utf-8?B?c3Jpbml2YXM=?= | last post by:
Hi All, I'm having a grid view(GridView1) with a hyperlink column.It's ID is Link1 I want to show a popup on hyperlink click. I'm using ajaxToolkit:ModalPopupExtender for that. But when i'm using...
4
by: Ty | last post by:
Hello all, I am creating a web site with Visual Stuido 2008. I am trying to use a java script file to create a busybox for login from this page http://blogs.crsw.com/mark/articles/642.aspx. I...
3
by: graphicssl | last post by:
Okay, so first of all, I'm a designer first and a light coder second (I'm only really trained with HTML and CSS). So I apologize for having to post about something that's probably super-trivial! ...
0
by: emmanuelkatto | last post by:
Hi All, I am Emmanuel katto from Uganda. I want to ask what challenges you've faced while migrating a website to cloud. Please let me know. Thanks! Emmanuel
1
by: nemocccc | last post by:
hello, everyone, I want to develop a software for my android phone for daily needs, any suggestions?
1
by: Sonnysonu | last post by:
This is the data of csv file 1 2 3 1 2 3 1 2 3 1 2 3 2 3 2 3 3 the lengths should be different i have to store the data by column-wise with in the specific length. suppose the i have to...
0
by: Hystou | last post by:
There are some requirements for setting up RAID: 1. The motherboard and BIOS support RAID configuration. 2. The motherboard has 2 or more available SATA protocol SSD/HDD slots (including MSATA, M.2...
0
marktang
by: marktang | last post by:
ONU (Optical Network Unit) is one of the key components for providing high-speed Internet services. Its primary function is to act as an endpoint device located at the user's premises. However,...
0
by: Hystou | last post by:
Most computers default to English, but sometimes we require a different language, especially when relocating. Forgot to request a specific language before your computer shipped? No problem! You can...
0
Oralloy
by: Oralloy | last post by:
Hello folks, I am unable to find appropriate documentation on the type promotion of bit-fields when using the generalised comparison operator "<=>". The problem is that using the GNU compilers,...
0
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven...
0
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each...

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.