Need Help With a Load

We are attemtping a load using a dump file. The load is being run from
an app server box (No 15) into a database server(box 13).

The load works ok but we are getting some errors ...some rows have bad
data.

We are attempting to capture the specific rows that are not being
loaded due to errors and are using a dump file.

Even though the permissions are ok we are getting error messages on
accessing the dump file. We understand that the dump file should be on
the database server and have tried placing it on either with the same
error.

Is a mount point for the dumpfile required in this situation?
Can you see what we are doing wrong?

Card and error message is below.

Thanks in advance.
Gerry
da*******@yahoo.com
The following is the script along with the error message. At the very
bottom is the path from which it is being run:

LOAD CLIENT FROM "/siebel/Sieb_ftt/IN/SCETCOV2" OF ASC MODIFIED BY
ANYORDER IDEN
TITYMISSING DUMPFILE = /home/siebel/logs/dumpit.log NULLINDCHAR=Y
METHOD L (208
241, 314 319, 308 313, 320 329, 173 202, 1 4, 5 6, 8 10, 11 13, 7 7, 91
109, 110
128, 74 78, 79 81, 14 43, 45 73, 82 84, 85 87, 88 90, 129 142, 143
172, 1 13, 2
08 237, 240 241, 238 239, 206 207, 203 205, 275 275, 242 260, 261 267,
268 274,
276 307) NULL INDICATORS (0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,
0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0) MESSAGES
"/siebel/Sieb_ftt/log/loadmsg
s.err" REPLACE INTO SIEBEL.EIM_FN_DEFADM (VAL_VALUE, ROW_ID,
IF_ROW_BATCH_NUM, I
F_ROW_STAT, DEF_ATTRIB_01, DEF_ATTRIB_03, DEF_ATTRIB_04, DEF_ATTRIB_06,
DEF_ATTR
IB_07, DEF_ATTRIB_08, DEF_ATTRIB_12, DEF_ATTRIB_26, DEF_ATTRIB_34,
DEF_ATTRIB_35
, DEF_ATTRIB_36, DEF_ATTRIB_37, DEF_ATTRIB_38, DEF_ATTRIB_39,
DEF_ATTRIB_40, DEF
_ATTRIB_41, DEF_ATTRIB_42, DEF_DEF_ADMIN_NUM, X_VAL_ATTRIB_03,
X_VAL_ATTRIB_04,
X_VAL_ATTRIB_05, X_VAL_ATTRIB_06, X_VAL_ATTRIB_07, X_VAL_ATTRIB_08,
X_VAL_ATTRIB
_12, X_VAL_ATTRIB_14, X_VAL_ATTRIB_15, X_VAL_ATTRIB_16)FOR EXCEPTION
SIEBEL.EIM_
ERR_TAB NONRECOVERABLE INDEXING MODE AUTOSELECT
SQL3508N Error in accessing a file or path of type "DUMPFILE" during
load or
load query. Reason code: "1". Path: "/home/siebel/logs/dumpit.log".

Nov 12 '05 #1
1 1534
Got it!!

The load was being run by a non-instance owner id. We had been trying
to make sure that that ID had permissions on the dumpfile....it has to
be the instance owner.

Nov 12 '05 #2

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

15
by: Tee | last post by:
Hi, I have a base usercontrol with a method (blank method, no code), I have another few usercontrols that will inherit this base usercontrol, but I want to force all the usercontrol that...
9
by: pankaj_wolfhunter | last post by:
Hi, I need some clearance on the following questions: 1) Does LOAD command updates indexes defined for a table? 2) Is REPLACE option in the LOAD command a logged operation? Help will be...
19
by: James Fortune | last post by:
I have a lot of respect for David Fenton and Allen Browne, but I don't understand why people who know how to write code to completely replace a front end do not write something that will automate...
3
by: B Maxey | last post by:
I am storing images in a database and need a way to browse those files. I can load the files into an image list or whatever the control needs, but I need a control. It doesn't seem that any of...
3
by: Shapper | last post by:
Hello, I am working on an ASP.NET/VB web site. I have several links including menu links. Considerer a want to load a page named page.aspx. I can do it using javascript. Or using this code:...
6
by: Lee Harr | last post by:
I have a database where I remove the schema public. When I try to use the createlang script, it fails like this ... >createdb foo CREATE DATABASE >psql foo -c "select version()" version...
0
by: dnphamus13 | last post by:
I'm new to this and drowning right now. I would like to put my database online for viewing. I managed to do the filtering but i need to do PAGING as the XML doc get bigger. From what i understand...
21
by: Johan Tibell | last post by:
I would be grateful if someone had a minute or two to review my hash table implementation. It's not yet commented but hopefully it's short and idiomatic enough to be readable. Some of the code...
1
by: donradii | last post by:
Hello all, I am new here and am new the world of javascripting. I am having a heck of a time trying to accomplish something that i conceptually know what i want to do but can not seem to get it...
5
by: Chuck Anderson | last post by:
I run Apache 2.0.55, and Php (both 4.4.1 and 5.2.5) on my home PC (Windows XP). One of the scripts that I run daily needs to access a secure URL (https://..............). When I am running Php4,...
0
by: ryjfgjl | last post by:
If we have dozens or hundreds of excel to import into the database, if we use the excel import function provided by database editors such as navicat, it will be extremely tedious and time-consuming...
0
by: ryjfgjl | last post by:
In our work, we often receive Excel tables with data in the same format. If we want to analyze these data, it can be difficult to analyze them because the data is spread across multiple Excel files...
0
by: emmanuelkatto | last post by:
Hi All, I am Emmanuel katto from Uganda. I want to ask what challenges you've faced while migrating a website to cloud. Please let me know. Thanks! Emmanuel
1
by: nemocccc | last post by:
hello, everyone, I want to develop a software for my android phone for daily needs, any suggestions?
1
by: Sonnysonu | last post by:
This is the data of csv file 1 2 3 1 2 3 1 2 3 1 2 3 2 3 2 3 3 the lengths should be different i have to store the data by column-wise with in the specific length. suppose the i have to...
0
by: Hystou | last post by:
There are some requirements for setting up RAID: 1. The motherboard and BIOS support RAID configuration. 2. The motherboard has 2 or more available SATA protocol SSD/HDD slots (including MSATA, M.2...
0
marktang
by: marktang | last post by:
ONU (Optical Network Unit) is one of the key components for providing high-speed Internet services. Its primary function is to act as an endpoint device located at the user's premises. However,...
0
Oralloy
by: Oralloy | last post by:
Hello folks, I am unable to find appropriate documentation on the type promotion of bit-fields when using the generalised comparison operator "<=>". The problem is that using the GNU compilers,...
0
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven...

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.