473,847 Members | 1,561 Online
Bytes | Software Development & Data Engineering Community
+ Post

Home Posts Topics Members FAQ

There is no available conversion for the source code page "1252" to the target code page "0". Reason Code "1". SQLSTATE=57017

nan
Hi All,
I am trying to connect the Database which is installed in AS400
using DB2 Client Version 8 in Windows box.
First i created the Catalog,

then when i selected the connection type as ODBC, then i am getting
following error, could any one please help in solving this issue?

ODBC connection failed.
[IBM][CLI Driver] SQL0332N There is no available conversion for the
source code page "1252" to the target code page "0". Reason Code "1".
SQLSTATE=57017


Thanks & Regards
Nanjayan

Dec 24 '05 #1
3 12020
nan wrote:
Hi All,
I am trying to connect the Database which is installed in AS400
using DB2 Client Version 8 in Windows box.

First i created the Catalog,

then when i selected the connection type as ODBC, then i am getting
following error, could any one please help in solving this issue?

ODBC connection failed.
[IBM][CLI Driver] SQL0332N There is no available conversion for the
source code page "1252" to the target code page "0". Reason Code "1".
SQLSTATE=57017

Nit: DB2 UDB for iSeries (AS/400) is part of the operating system
(OS/400). It is not "installed" .

Below the text for iSeries message SQL0332 is shown. You might check
into the CCSID value assigned to the (iSeries) user profile you are
using to CONNECT. It may need to be changed if it is currently set to
0. Or if it is set to *SYSVAL use this command to check the value of
QCCSID system value: wrksysval qccsid
Just some things to look into...
wrkmsgd sql0332 qsqlmsg

Message ID . . . . . . . . . : SQL0332

Message file . . . . . . . . : QSQLMSG

Library . . . . . . . . . : QSYS

Message . . . . : Character conversion between CCSID &1 and CCSID &2
not valid.

Cause . . . . . : Character or graphic conversion has been attempted
for data that is not compatible. There is no conversion defined between
CCSID &1 and CCSID &2.

If one CCSID is 65535, the other CCSID is a graphic CCSID. Conversion is
not defined between 65535 and a graphic CCSID. If this is a CONNECT
statement, conversion is not defined between the default application
requester SBCS CCSID and the application server SBCS CCSID. If the
second CCSID is 0, the application server did not return its default
SBCS CCSID. An application server other than an iSeries may not support
a CCSID of 65535.
Recovery . . . : Ensure that all character or graphic comparisons,
concatenation, or assignments are between columns or host variables with
compatible CCSID values.
If this is a CONNECT statement, change either the SBCS CCSID of the
application requester or the application server, so conversion between
the CCSID values is defined.

--
Karl Hanson
Dec 27 '05 #2
Karl Hanson wrote:
Nit: DB2 UDB for iSeries (AS/400) is part of the operating system
(OS/400). It is not "installed" .


If operating system on AS/400 was installed (in manufacturing or by customer; it
doesn't matter how) - then any part of it (for example DB2/400) was also
installed, right?

Jan M. Nelken
Dec 28 '05 #3
Jan M. Nelken wrote:
Karl Hanson wrote:
Nit: DB2 UDB for iSeries (AS/400) is part of the operating system
(OS/400). It is not "installed" .

If operating system on AS/400 was installed (in manufacturing or by
customer; it doesn't matter how) - then any part of it (for example
DB2/400) was also installed, right?


Correct. There is no separate product to install for SQL etc. There
are some separate products such as 5722ST1 (Query Mgr & DevKit) that
provide for example an interactive SQL interface.

http://www.ibm.com/servers/eserver/i...b2/db2faq.html

Note: There are some optionally installable parts of OS/400, such as
Option 1 : Extended Base Support. However DB2 is not one of those.

--
Karl Hanson
Dec 28 '05 #4

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

0
2188
by: Dmitry Bond | last post by:
Hi All. I'm trying to connect DB2 8.1 server remotely via DB2 7.2 Client Configuration Assistant. But is displays the following error message: ===error=== The search for databases on the network failed. SQL0332N There is no available conversion for the source code page "1252" to the target code page "1251". Reason Code "3". SQLSTATE=57017 For additional information, press the help button. Correct the problem
12
1698
by: Thames | last post by:
I just did some replication operations between remote DB on linux and local DB on windows yesterday It gave me such errors when I perform db connection via command line windows (local DB on windows) error is given as follow: ***************************************** Db2 connect to SAMPLE SQL0332N There is no available conversion for the source code page "1252" to
2
6194
by: Thames | last post by:
Hi, I have to repost my question for help. Yesterday I set up two DB UDB ESE V8.2 server on linux and windows platform, respectively. Both servers have been connected without any problems However, It gave me such error when I tried to make db connection via command prompt(windows)
0
3124
by: Yoav | last post by:
Hello, I have been trying to enter SQL statmenbts to DB2 control center command line. I saw that user "Thames" wrote to you: > I have to repost my question for help. > > Yesterday I set up two DB UDB ESE V8.2 server on linux and windows > platform, respectively. Both servers have been connected without any > problems > However, It gave me such error when I tried to make db connection via > command prompt(windows)
0
9735
by: Hystou | last post by:
Most computers default to English, but sometimes we require a different language, especially when relocating. Forgot to request a specific language before your computer shipped? No problem! You can effortlessly switch the default language on Windows 10 without reinstalling. I'll walk you through it. First, let's disable language synchronization. With a Microsoft account, language settings sync across devices. To prevent any complications,...
0
10996
Oralloy
by: Oralloy | last post by:
Hello folks, I am unable to find appropriate documentation on the type promotion of bit-fields when using the generalised comparison operator "<=>". The problem is that using the GNU compilers, it seems that the internal comparison operator "<=>" tries to promote arguments from unsigned to signed. This is as boiled down as I can make it. Here is my compilation command: g++-12 -std=c++20 -Wnarrowing bit_field.cpp Here is the code in...
0
10658
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven tapestry of website design and digital marketing. It's not merely about having a website; it's about crafting an immersive digital experience that captivates audiences and drives business growth. The Art of Business Website Design Your website is...
1
10718
by: Hystou | last post by:
Overview: Windows 11 and 10 have less user interface control over operating system update behaviour than previous versions of Windows. In Windows 11 and 10, there is no way to turn off the Windows Update option using the Control Panel or Settings app; it automatically checks for updates and installs any it finds, whether you like it or not. For most users, this new feature is actually very convenient. If you want to control the update process,...
0
10347
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each protocol has its own unique characteristics and advantages, but as a user who is planning to build a smart home system, I am a bit confused by the choice of these technologies. I'm particularly interested in Zigbee because I've heard it does some...
1
7889
isladogs
by: isladogs | last post by:
The next Access Europe User Group meeting will be on Wednesday 1 May 2024 starting at 18:00 UK time (6PM UTC+1) and finishing by 19:30 (7.30PM). In this session, we are pleased to welcome a new presenter, Adolph Dupré who will be discussing some powerful techniques for using class modules. He will explain when you may want to use classes instead of User Defined Types (UDT). For example, to manage the data in unbound forms. Adolph will...
0
7062
by: conductexam | last post by:
I have .net C# application in which I am extracting data from word file and save it in database particularly. To store word all data as it is I am converting the whole word file firstly in HTML and then checking html paragraph one by one. At the time of converting from word file to html my equations which are in the word document file was convert into image. Globals.ThisAddIn.Application.ActiveDocument.Select();...
0
5915
by: adsilva | last post by:
A Windows Forms form does not have the event Unload, like VB6. What one acts like?
2
4133
muto222
by: muto222 | last post by:
How can i add a mobile payment intergratation into php mysql website.

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.