473,399 Members | 3,888 Online
Bytes | Software Development & Data Engineering Community
Post Job

Home Posts Topics Members FAQ

Join Bytes to post your question to a community of 473,399 software developers and data experts.

CDO Error

I have the following ASP code on a simple "experimental" page:

<%
Set myMail=CreateObject("CDO.Message")
myMail.Subject="Sending email with CDO"
myMail.From="f...@blah.com"
myMail.To="t...@blah.com"
myMail.CreateMHTMLBody "http://cic/targeted/results.asp"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/sendusing")=2
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserver")="172.30.8.51"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserverport")=25
mymail.configuration.fields.update
myMail.Send
set myMail=nothing
%>
When attempting to hit this page, I receive:
CDO.Message.1 error '80070005'
Access is denied.
/experiments/emailtest.asp, line 6
I ran LogMon, and found the following error whenever I hit the page:
4:49:37 PM w3wp.exe:2992 OPEN D:\CIC ACCESS DENIED NT
AUTHORITY
\NETWORK SERVICE
I've tried adding the network service user to D:\CIC, but the same
error persists.
Any ideas?

Oct 24 '07 #1
4 3393
"Nate" <na**********@westecnow.comwrote in message
news:11*********************@q3g2000prf.googlegrou ps.com...
I have the following ASP code on a simple "experimental" page:

<%
Set myMail=CreateObject("CDO.Message")
myMail.Subject="Sending email with CDO"
myMail.From="f...@blah.com"
myMail.To="t...@blah.com"
myMail.CreateMHTMLBody "http://cic/targeted/results.asp"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/sendusing")=2
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserver")="172.30.8.51"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserverport")=25
mymail.configuration.fields.update
myMail.Send
set myMail=nothing
%>
When attempting to hit this page, I receive:
CDO.Message.1 error '80070005'
Access is denied.
/experiments/emailtest.asp, line 6
I ran LogMon, and found the following error whenever I hit the page:
4:49:37 PM w3wp.exe:2992 OPEN D:\CIC ACCESS DENIED NT
AUTHORITY
\NETWORK SERVICE
I've tried adding the network service user to D:\CIC, but the same
error persists.
Did you grant read/write access?
What is D:\CIC anyway, a folder or root of the website?
Is this code running on CIC?
If you visit http://cic/targeted/results.asp with a browser does it work?
Do you have ASP debugging turned on?

Having asked that lot, CreateMHTMLBody isn't a safe thing to using in ASP.
Ultimately it will use the WinINet API which is designed to be used by a
client. If you have many such requests running at the same time all sorts
of undesirable things can happen.

--
Anthony Jones - MVP ASP/ASP.NET
Oct 24 '07 #2
On Oct 24, 4:32 pm, "Anthony Jones" <A...@yadayadayada.comwrote:
"Nate" <nate.borl...@westecnow.comwrote in message

news:11*********************@q3g2000prf.googlegrou ps.com...


I have the following ASP code on a simple "experimental" page:
<%
Set myMail=CreateObject("CDO.Message")
myMail.Subject="Sending email with CDO"
myMail.From="f...@blah.com"
myMail.To="t...@blah.com"
myMail.CreateMHTMLBody "http://cic/targeted/results.asp"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/sendusing")=2
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserver")="172.30.8.51"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserverport")=25
mymail.configuration.fields.update
myMail.Send
set myMail=nothing
%>
When attempting to hit this page, I receive:
CDO.Message.1 error '80070005'
Access is denied.
/experiments/emailtest.asp, line 6
I ran LogMon, and found the following error whenever I hit the page:
4:49:37 PM w3wp.exe:2992 OPEN D:\CIC ACCESS DENIED NT
AUTHORITY
\NETWORK SERVICE
I've tried adding the network service user to D:\CIC, but the same
error persists.

Did you grant read/write access?
What is D:\CIC anyway, a folder or root of the website?
Is this code running on CIC?
If you visithttp://cic/targeted/results.aspwith a browser does it work?
Do you have ASP debugging turned on?

Having asked that lot, CreateMHTMLBody isn't a safe thing to using in ASP.
Ultimately it will use the WinINet API which is designed to be used by a
client. If you have many such requests running at the same time all sorts
of undesirable things can happen.

--
Anthony Jones - MVP ASP/ASP.NET- Hide quoted text -

- Show quoted text -
Thanks for the response, Anthony.

Read and write access (even full access) was tested and failed. D:\CIC
is the root of the site on the server. Yes, the code is running on
CIC. Yes, the page works properly. I may not have had ASP debugging
turned on, but will try again.
Oct 24 '07 #3
On Oct 24, 6:48 pm, Nate <nate.borl...@westecnow.comwrote:
On Oct 24, 4:32 pm, "Anthony Jones" <A...@yadayadayada.comwrote:


"Nate" <nate.borl...@westecnow.comwrote in message
news:11*********************@q3g2000prf.googlegrou ps.com...
I have the following ASP code on a simple "experimental" page:
<%
Set myMail=CreateObject("CDO.Message")
myMail.Subject="Sending email with CDO"
myMail.From="f...@blah.com"
myMail.To="t...@blah.com"
myMail.CreateMHTMLBody "http://cic/targeted/results.asp"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/sendusing")=2
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserver")="172.30.8.51"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserverport")=25
mymail.configuration.fields.update
myMail.Send
set myMail=nothing
%>
When attempting to hit this page, I receive:
CDO.Message.1 error '80070005'
Access is denied.
/experiments/emailtest.asp, line 6
I ran LogMon, and found the following error whenever I hit the page:
4:49:37 PM w3wp.exe:2992 OPEN D:\CIC ACCESS DENIED NT
AUTHORITY
\NETWORK SERVICE
I've tried adding the network service user to D:\CIC, but the same
error persists.
Did you grant read/write access?
What is D:\CIC anyway, a folder or root of the website?
Is this code running on CIC?
If you visithttp://cic/targeted/results.aspwitha browser does it work?
Do you have ASP debugging turned on?
Having asked that lot, CreateMHTMLBody isn't a safe thing to using in ASP.
Ultimately it will use the WinINet API which is designed to be used by a
client. If you have many such requests running at the same time all sorts
of undesirable things can happen.
--
Anthony Jones - MVP ASP/ASP.NET- Hide quoted text -
- Show quoted text -

Thanks for the response, Anthony.

Read and write access (even full access) was tested and failed. D:\CIC
is the root of the site on the server. Yes, the code is running on
CIC. Yes, the page works properly. I may not have had ASP debugging
turned on, but will try again.- Hide quoted text -

- Show quoted text -
Yes, debugged was enabled.

Oct 24 '07 #4
"Nate" <na**********@westecnow.comwrote in message
news:11**********************@e9g2000prf.googlegro ups.com...
On Oct 24, 6:48 pm, Nate <nate.borl...@westecnow.comwrote:
On Oct 24, 4:32 pm, "Anthony Jones" <A...@yadayadayada.comwrote:


"Nate" <nate.borl...@westecnow.comwrote in message
>news:11*********************@q3g2000prf.googlegro ups.com...
I have the following ASP code on a simple "experimental" page:
<%
Set myMail=CreateObject("CDO.Message")
myMail.Subject="Sending email with CDO"
myMail.From="f...@blah.com"
myMail.To="t...@blah.com"
myMail.CreateMHTMLBody "http://cic/targeted/results.asp"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/sendusing")=2
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserver")="172.30.8.51"
mymail.configuration.fields.item("http://schemas.microsoft.com/cdo/
configuration/smtpserverport")=25
mymail.configuration.fields.update
myMail.Send
set myMail=nothing
%>
When attempting to hit this page, I receive:
CDO.Message.1 error '80070005'
Access is denied.
/experiments/emailtest.asp, line 6
I ran LogMon, and found the following error whenever I hit the page:
4:49:37 PM w3wp.exe:2992 OPEN D:\CIC ACCESS DENIED NT
AUTHORITY
\NETWORK SERVICE
I've tried adding the network service user to D:\CIC, but the same
error persists.
Did you grant read/write access?
What is D:\CIC anyway, a folder or root of the website?
Is this code running on CIC?
If you visithttp://cic/targeted/results.aspwitha browser does it work?
Do you have ASP debugging turned on?
Having asked that lot, CreateMHTMLBody isn't a safe thing to using in
ASP.
Ultimately it will use the WinINet API which is designed to be used by
a
client. If you have many such requests running at the same time all
sorts
of undesirable things can happen.
--
Anthony Jones - MVP ASP/ASP.NET- Hide quoted text -
- Show quoted text -
Thanks for the response, Anthony.

Read and write access (even full access) was tested and failed. D:\CIC
is the root of the site on the server. Yes, the code is running on
CIC. Yes, the page works properly. I may not have had ASP debugging
turned on, but will try again.- Hide quoted text -

- Show quoted text -

Yes, debugged was enabled.
When debugging is turned on ASP will only use one worker thread to handle
requests. If your ASP code performs an action which generates another
request into the site that request will queue waiting for you ASP code to
complete. However your ASP code won't complete until its received a
response from the second request. Its a deadlock. Eventually the second
request will timeout and you'd get an error, Access denied is not what I
would expect to be the result though.

Do you have anonymous access turned on?

Note having ASP code generate requests to other ASP pages running in the
same application can also be a source of problems when used heavily. You
can end up with deadlock even without debugging turned on.

--
Anthony Jones - MVP ASP/ASP.NET
Oct 25 '07 #5

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

2
by: AIM | last post by:
Error in msvc in building inheritance.obj to build hello.pyd Hello, I am trying to build the boost 1.31.0 sample extension hello.cpp. I can not compile the file inheritance.cpp because the two...
2
by: Gregory | last post by:
Hi, One of the disadvantages of using error handling with error codes instead of exception handling is that error codes retuned from a function can be forgotten to check thus leading to...
13
by: deko | last post by:
I use this convention frequently: Exit_Here: Exit Sub HandleErr: Select Case Err.Number Case 3163 Resume Next Case 3376 Resume Next
7
by: p | last post by:
WE had a Crystal 8 WebApp using vs 2002 which we upgraded to VS2003. I also have Crystal 9 pro on my development machine. The web app runs fine on my dev machine but am having problems deploying....
3
by: Manuel | last post by:
I'm trying to compile glut 3.7.6 (dowbloaded from official site)using devc++. So I've imported the glut32.dsp into devc++, included manually some headers, and start to compile. It return a very...
0
by: bazzer | last post by:
hey, im trying to access a microsoft access database from an ASP.NET web application in visual basic 2003.NET. i get the following error when i try running it: Server Error in...
1
by: developer | last post by:
Hi All I have made a .NET project. the files included are borland c++ files that i am migrate to VC++ .NET I am using Microsoft Visual C++ .NET 2003. the compilation goes through properly,...
0
by: mchuc7719 | last post by:
Hello, I have a Vb.Net 2005 ClassLibrary, when I try to compile using MSBee, only get errors. Before I to run the command line, I open in notepad the .vbproj and I was add the next line: ...
2
hyperpau
by: hyperpau | last post by:
Before anything else, I am not a very technical expert when it comes to VBA coding. I learned most of what I know by the excellent Access/VBA forum from bytes.com (formerly thescripts.com). Ergo, I...
0
hyperpau
by: hyperpau | last post by:
Before anything else, I am not a very technical expert when it comes to VBA coding. I learned most of what I know by the excellent Access/VBA forum from bytes.com (formerly thescripts.com). Ergo, I...
0
by: Charles Arthur | last post by:
How do i turn on java script on a villaon, callus and itel keypad mobile phone
0
by: emmanuelkatto | last post by:
Hi All, I am Emmanuel katto from Uganda. I want to ask what challenges you've faced while migrating a website to cloud. Please let me know. Thanks! Emmanuel
1
by: nemocccc | last post by:
hello, everyone, I want to develop a software for my android phone for daily needs, any suggestions?
1
by: Sonnysonu | last post by:
This is the data of csv file 1 2 3 1 2 3 1 2 3 1 2 3 2 3 2 3 3 the lengths should be different i have to store the data by column-wise with in the specific length. suppose the i have to...
0
by: Hystou | last post by:
There are some requirements for setting up RAID: 1. The motherboard and BIOS support RAID configuration. 2. The motherboard has 2 or more available SATA protocol SSD/HDD slots (including MSATA, M.2...
0
by: Hystou | last post by:
Most computers default to English, but sometimes we require a different language, especially when relocating. Forgot to request a specific language before your computer shipped? No problem! You can...
0
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven...
0
by: Hystou | last post by:
Overview: Windows 11 and 10 have less user interface control over operating system update behaviour than previous versions of Windows. In Windows 11 and 10, there is no way to turn off the Windows...
0
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each...

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.