Corruption?

I'm redesigning a report in my frontend. When I move a text object,
sometimes Access gives a message that Access has to be closed. After opening
or compact and repair the mdb works fine again. Do I have to worry about
this? Should I move all the objects to a new mdb?
Thank you.
John
Nov 26 '07 #1
2 1338
jo****@johnie.com wrote:
I'm redesigning a report in my frontend. When I move a text object,
sometimes Access gives a message that Access has to be closed. After opening
or compact and repair the mdb works fine again. Do I have to worry about
this? Should I move all the objects to a new mdb?
Thank you.
John

What you could try first is:
You could open your mdb with a /decompile. That might fix it. Compact
after decompile, then remove the decompile switch and see if it works.
If not.

When the mdb opens then open a new report and the current report in
design mode. Then highlight all objects per band in the current report
and drop them in the new report. Then do the same for the code. Close
the reports and rename the new report to the old report name. Then compact.

If that doesn't work you can try bringing over all the objects to a new mdb.
Nov 27 '07 #2
"Salad" <oi*@vinegar.comschreef in bericht
news:13*************@corp.supernews.com...
What you could try first is:
You could open your mdb with a /decompile. That might fix it. Compact
after decompile, then remove the decompile switch and see if it works. If
not.

When the mdb opens then open a new report and the current report in design
mode. Then highlight all objects per band in the current report and drop
them in the new report. Then do the same for the code. Close the reports
and rename the new report to the old report name. Then compact.

If that doesn't work you can try bringing over all the objects to a new
mdb.
Thanks a lot!
John
Nov 27 '07 #3

This thread has been closed and replies have been disabled. Please start a new discussion.

Similar topics

5
by: Noa Garnett | last post by:
I'm developing on C++, using visual studio 6.0 with service pack 5. I have a memory corruption while debugging. Some of the variables I'm using are suddenly set to zero while progressing along the...
10
by: Arno R | last post by:
Hi all Yesterday I found a strange corruption-issue that I can't solve yet or actually point my finger at. I converted an A97 app to A2k. I have done this often enough so I didn't expect trouble...
19
by: Mark C. | last post by:
The company I work for has been running Access 2000 on a Windows NT server with Opportunistic Locking turned off on the server without issue for almost a year. We have just switched to a Windows...
6
by: Mike | last post by:
I have done a lot of research on DAO and database corruption and have not yet found any solid information for my problem. I use DAO extensively in my Access 97 databases (back-end on network,...
4
by: DFS | last post by:
" has detected corruption in this file. To try to repair the corruption, first make a backup copy of the file. Then, on the Tools menu, point to Database Utilities and click Compact and Repair...
47
by: ship | last post by:
Hi We need some advice: We are thinking of upgrading our Access database from Access 2000 to Access 2004. How stable is MS Office 2003? (particularly Access 2003). We are just a small...
8
by: ranjeet.gupta | last post by:
Dear All Is the Root Cause of the Memory corruption is the Memory leak, ?? suppose If in the code there is Memory leak, Do this may lead to the Memory Corruption while executing the program ? ...
23
by: Dave G | last post by:
Since upgrading one of my clients from A97/W2000 to A2003/XP they have suffered no end of data corruption problems, mainly involving one of the main tables. The corruption can result in one...
2
by: nepdae | last post by:
Please forgive me, this is a long one. My 11-user Access 2000 database is having recurring corruption problems. The symptoms include the following: 1) corrupted fields in recently created or...
42
by: Doug | last post by:
I am in a friendly debate with some co-workers... and my boss. We use Access 2003 for the frontend (on workstations) as well as for the backend (on a Dell PowerEdge running Windows 2000 server,...
0
by: Charles Arthur | last post by:
How do i turn on java script on a villaon, callus and itel keypad mobile phone
0
BarryA
by: BarryA | last post by:
What are the essential steps and strategies outlined in the Data Structures and Algorithms (DSA) roadmap for aspiring data scientists? How can individuals effectively utilize this roadmap to progress...
0
by: Hystou | last post by:
There are some requirements for setting up RAID: 1. The motherboard and BIOS support RAID configuration. 2. The motherboard has 2 or more available SATA protocol SSD/HDD slots (including MSATA, M.2...
0
marktang
by: marktang | last post by:
ONU (Optical Network Unit) is one of the key components for providing high-speed Internet services. Its primary function is to act as an endpoint device located at the user's premises. However,...
0
by: Hystou | last post by:
Most computers default to English, but sometimes we require a different language, especially when relocating. Forgot to request a specific language before your computer shipped? No problem! You can...
0
Oralloy
by: Oralloy | last post by:
Hello folks, I am unable to find appropriate documentation on the type promotion of bit-fields when using the generalised comparison operator "<=>". The problem is that using the GNU compilers,...
0
jinu1996
by: jinu1996 | last post by:
In today's digital age, having a compelling online presence is paramount for businesses aiming to thrive in a competitive landscape. At the heart of this digital strategy lies an intricately woven...
0
tracyyun
by: tracyyun | last post by:
Dear forum friends, With the development of smart home technology, a variety of wireless communication protocols have appeared on the market, such as Zigbee, Z-Wave, Wi-Fi, Bluetooth, etc. Each...
0
isladogs
by: isladogs | last post by:
The next Access Europe User Group meeting will be on Wednesday 1 May 2024 starting at 18:00 UK time (6PM UTC+1) and finishing by 19:30 (7.30PM). In this session, we are pleased to welcome a new...

By using Bytes.com and it's services, you agree to our Privacy Policy and Terms of Use.

To disable or enable advertisements and analytics tracking please visit the manage ads & tracking page.